SOLUTIONS
The 21st century is the era of natural gas. At present, the proportion of natural gas in the energy mix is increasing day by day, and it has become the third largest energy source worldwide after coal and oil, gradually becoming the main alternative energy source to coal. The sustainable and rapid development of the Chinese economy requires accelerating the transition from traditional energy economy to clean energy economy, and developing the LNG industry is an important component of the clean energy strategy. The national 12th Five Year Energy Strategy Plan requires a rapid expansion of the proportion of natural gas in the energy structure, and the rapid development of technology development, large-scale production, and industrial operation related to the liquefied natural gas industry has sprung up like mushrooms across the country. Advanced and sophisticated automation equipment plays a crucial role in the liquefied natural gas industry, and is widely valued for its application in LNG storage tank systems and instrument selection and installation under cryogenic conditions (-170 ℃).
This article analyzes the instrument selection, design, and installation schemes applied in LNG storage tank systems from three aspects: temperature, pressure, and liquid level.
1 Temperature instrument
For LNG projects, the focus of temperature measurement is on multi-point thermometers used in LNG storage tanks. The temperature instrument installed in the LNG storage tank is not only used for temperature detection, but also detects whether there is LNG leakage through temperature changes; And real-time monitoring of temperature is carried out during the pre cooling process of LNG storage tanks to control the entire pre cooling process.
Multi point thermometers for storage tanks are mainly used in the following areas:
1.1 Multiple point thermometers are installed on the inner wall, bottom, and ceiling of LNG storage tanks to monitor temperature during pre cooling and operation processes.
1.2 Multiple point thermometers are also installed in the annular space between the outer and inner tanks of LNG storage tanks to detect tank leaks through temperature changes.
Taking the inner tank wall and inner tank bottom as examples, this article introduces the application and installation of multi-point thermometers for storage tanks.
The thermal resistance end of the multi-point thermometer for the storage tank is fixed to the inner wall or bottom of the tank with a heat collecting block, and laid upwards along the tank wall. An expansion bend is made every 3 meters and fixed to the tank wall with an installation bracket. Then, it is connected to the junction box outside the tank top through the porous flange of the LNG storage tank equipment hole (the number and size of the flange hole are determined according to the actual situation). Finally, the pt100 signal is remotely transmitted to the control system through a multi-core cable, or converted into a 4-20mA signal through a transmitter for remote transmission.
Next, let's introduce the surface thermometer.
Surface thermometers are installed on the surface of LNG feed and export pipelines to measure the temperature of the pipe wall, achieving real-time detection of leaks in LNG feed and export pipelines, and avoiding major accidents; And the pre cooling situation of the entire process can be monitored through temperature changes. For low-temperature liquid phase pipelines with a nominal diameter of ≥ 8 ", surface thermometers are installed, with two temperature measurement points per group located at the bottom and top of the pipeline, and the distance between adjacent temperature measurement points is not more than 100m. Here, dual resistance thermometers are used, with the ends of the two resistance thermometers fixed to the top and bottom of the pipeline using collector blocks, and a split type temperature transmitter installed next to the pipeline to remotely transmit the signal to the control system.
The term 'pre cooling' has been mentioned multiple times in the previous text, and the pre cooling process is an important step before the entire device is officially started. Pre cooling refers to the use of low-temperature materials such as liquid natural gas or liquid nitrogen to cool all low-temperature pipelines, equipment, and storage tanks to the operating temperature of LNG (-161 ℃). The entire pre cooling process gradually changes from room temperature (outdoor temperature) to -161 ℃, so it is recommended that the range of the thermometer be selected between 30 ℃ and -170 ℃.
2 Pressure gauges
Due to the fact that the measured medium is liquid natural gas and the operating temperature is -170 ℃, a split type online pressure measurement method is required for measurement. Therefore, in order to save costs, a pressure transmitter is used in LNG plants to measure the pressure of low-temperature media.
For online pressure measurement of low-temperature media, in order to protect the transmitter from damage due to low temperature, it must be vaporized before measurement. When LNG is vaporized, its volume ratio is 1:600, which will instantly generate huge pressure and cause unpredictable damage to the instrument. Therefore, it is necessary to gasify LNG as slowly as possible, and here we need to use a flow restriction orifice flange (see "Figure 2-1 Flow restriction orifice flange").
Figure 2-1 Flow restriction orifice flange
The limiting orifice flange serves as a socket weld flange conversion joint, with a 2mm small hole on one side of the interface with the pipeline equipment. This can slow down the LNG gasification rate and provide cold insulation for the inlet side of the pressure pipe, thus achieving the purpose of protecting the transmitter diaphragm box.
3 liquid level instruments
In the LNG storage tank instrumentation system, measuring the tank level is another key focus. In low-temperature environments, it is not only necessary to measure, alarm, and interlock the liquid level, but also to predict the rolling state of the LNG medium in the storage tank through a liquid level gauge.
A liquid level measurement system for an LNG storage tank consists of one LTD level/temperature/density meter, two servo level meters, two 16 point average thermometers (for temperature compensation of servo level meters), one radar level meter, and one tank side display instrument. The functions of each level meter are as follows:
3.1 LTD liquid level temperature density meter, used to measure the liquid level, temperature, and density of storage tanks. LTD has a multi-point distribution and can perform specific distribution measurements at any height, displaying temperature and density with an accuracy of T ± 0.1 ℃ and D ± 0.05kg/m3; LTD's probe can move throughout the entire tank height range for liquid level measurement, with an accuracy of L ± 2mm. The LTD output signal is transmitted to the control room through the RS-485 communication protocol.
3.2 Servo level gauges, one LNG storage tank is equipped with two servo level gauges for measurement and local/remote display, with an accuracy of ± 0.4mm for liquid level, ± 0.1mm for sensitivity, and ± 0.1mm for repeatability;
And the servo level gauge has a highly reliable alarm function, which can provide high, high high, low, and low low level alarms. The low low level alarm of two servo level gauges is used as a binary interlock to stop the loading pump, and the high high level alarm of two servo level gauges and the high high level alarm of the radar level gauge are used as a binary interlock to close the feeding valve. The output signal of the servo level gauge is transmitted to the control room through the communication bus.
3.3 Average thermometer, each servo level gauge is equipped with a 16 point average thermometer for temperature compensation and can provide temperature distribution information of LNG average thermometer with an accuracy of < ± 0.1 ℃. The average temperature signal is connected to the servo level gauge through the HART protocol. And the servo level gauge can be roughly calibrated by an average thermometer. If the temperature at this point reaches below -160 ℃, it proves that the LNG level has reached this height.
3.4 Radar level gauge, used for high high level alarm, and can continuously measure the liquid level of LNG in the storage tank with a measurement accuracy of ± 3mm. The radar level gauge outputs on-site liquid level, instrument status, and other information to the control room through a communication bus.
3.5 Tank side display instrument, 2 servo level gauges can be configured with 1 tank side display instrument, used for on-site display of various status information such as temperature, average temperature, liquid level, density, volume, mass, and alarm.